BOILERWATCH® MMP II- SSX
The BOILERWATCH® MMP II-
The system is completely non-
Acoustic transceivers are mounted on the outside of walls of the heater/boiler, and a high intensity acoustic signal is transmitted through the gas stream.
Since the distance between the sound source and receiver is known and fixed, the average temperature of the gas along the acoustic path is computed from an accurate measurement of the sound signal’s transit time.
BOILERWATCH® MMP II-

3O2OTR- SSL Transceiver Unit Wave Guide and Preamplifier
Pneumatically driven acoustic sound source and receiver. Mounts on exterior furnace /heater wall, and provides acoustic transmitter and receiver functions for balanced-


BOILERWATCH® MMP- II- SSX
Processor Control Unit (PCU)
Provides temperature measurement capacity for up to eight (8) independent paths , or up to a twenty-

TMSIS- 4000
Features include: Industrial computer with pre-

Typical Configuration

3020TR-SSL Transceiver Unit - Wave Guide and Preamplifier
Wave Guide
Material: Stainless Steel 316L
Dimensions: 8 inch flange diameter, 14 inch length
Flange: In accordance with ASTM standard 3-
Weight: 26 lb. (11,8 Kg.)
Temperature Environment: Flange: +450ºF (+232ºC) max.; Ambient Air: +130ºF (+54ºC) max.
Noise generated: Inside: 126bB. Outside: 0dB
Preamplifier
Ambient Air Temperature: + 140 ºF (60ºC) maximum, No solar loading on cabinet
Enclosure: 6 in x 12in x 10in
Weight: 14 lb (6,4 Kg)
Industrial Standards: NEMA/EEMAC Type 4,12, 13. IEC 60529, IP66
BOILERWATCH® MMP-II-SSX Processor Control Unit (PCU)
Ambient Air Temperature: + 130 ºF (54ºC) maximum, No solar loading on cabinet
Enclosure: 30in x 24in x 12in
Weight: 110 lb (50Kg)
Industrial Standards: NEMA/EEMAC Type 4,12, 13. IEC 60529, IP66
TMSIS-4000
Number of Ports: Two minimum and up to sixteen maximum
Number of Paths: Up to twenty-four (24) paths
Measurement Range: 32ºF to 3500 ºF (0ºC to 1927 ºC)
Temperature Units: English or Metric (ºF or ºC)
Resolution: 12 ºF (6.7 ºC) for 20 meter path length @ 2000 ºF (1093ºC)
Accuracy: 5 seconds per path typical
Measurement Acquisition Time: Better than 0.5%
Data Output: OPC/Ethernet
AC Power Input: 120 to 240 VAC, 50/60 Hz.
Air Pressure to Sound Source: Air Service. 60 – 120 psig (5.0 – 8.3 Bar).
Air consumption: 5 bar = 2.26 m3/min (No Constant)
Warranty: Two (2) years.